Skip to content

Electrical Load Calculator — Domestic Property

Calculate the total electrical load for a UK domestic property. Enter the number of each appliance to see the total connected load and estimated maximum demand with diversity.

Enter quantity of each appliance

Kettle3.0kW each
Electric Oven3.0kW each
Electric Hob6.0kW each
Washing Machine2.5kW each
Tumble Dryer2.5kW each
Dishwasher1.8kW each
Microwave1.0kW each
Fridge-Freezer0.1kW each
Electric Shower (8.5kW)8.5kW each
Electric Shower (9.5kW)9.5kW each
Electric Shower (10.5kW)10.5kW each
Immersion Heater3.0kW each
EV Charger (7kW)7.0kW each
EV Charger (3.6kW)3.6kW each
Storage Heater (2kW)2.0kW each
Electric Radiator (2kW)2.0kW each
Towel Rail0.3kW each
Television0.1kW each
Computer / Monitor0.3kW each
Lighting (per circuit)1.2kW each

How We Calculate This

This calculator lists common UK domestic appliances with their typical wattage ratings. You enter the quantity of each appliance in your property, and the calculator determines both the total connected load and the estimated maximum demand using diversity factors.

The calculation

Connected Load = Sum of (quantity × rated watts) for all appliances

Maximum Demand = Sum of (connected load × diversity factor) for all appliances

Current (Amps) = Watts ÷ 230V

Typical appliance wattages

  • Kettle: 3,000W (diversity 10% — intermittent use)
  • Oven: 3,000W (diversity 60% — not always at full power)
  • Electric Hob: 6,000W (diversity 50% — rarely all rings at full)
  • Washing Machine: 2,500W (diversity 30%)
  • Electric Shower: 8,500-10,500W (diversity 100% — full load when on)
  • Immersion Heater: 3,000W (diversity 100%)
  • EV Charger: 3,600-7,000W (diversity 100% — continuous load)

The diversity factors used are based on typical domestic usage patterns and BS 7671 Table 1B guidance. Actual usage may vary — this provides a reasonable estimate for supply sizing purposes.

Frequently Asked Questions

Last updated: February 2026

All calculations are estimates. Verify with your supplier.