Pipe Insulation Calculator — How Much Pipe Lagging Do I Need?

Calculate pipe insulation quantities to meet Building Regulations and BS 5422. Includes elbows and tape.

External diameter of pipe

Total length of pipe runs to insulate

Include wastage allowance

Adds 15% for cuts, joins and fitting

15% recommended for pipe runs with bends

Include elbows/bends

Add extra for pipe bends

Count 90° bends in your pipe runs

Include tape

PVC or self-amalgamating tape for joints

Price per 1m piece

How We Calculate This

This calculator works out pipe insulation quantities based on your total pipe run length, pipe diameter, and chosen insulation material. It includes the minimum thickness required by BS 5422 (the British Standard for pipe insulation).

The formula

Pieces = (Total pipe length × Wastage factor ÷ Piece length) + Elbow extras

Minimum thicknesses (BS 5422)

  • 15-28mm pipe (foam): 19mm wall thickness
  • 15-28mm pipe (mineral wool): 25mm wall thickness
  • 35-54mm pipe (foam): 25mm wall thickness
  • 35-54mm pipe (mineral wool): 30-40mm wall thickness

Standard piece lengths

  • Foam tubes: 1m lengths
  • Mineral wool sections: 1m lengths
  • Rubber (Armaflex): 2m lengths
  • Phenolic foam: 1m lengths