Flue Liner Calculator — What Size Flue Liner Do I Need?

Calculate the correct flue liner diameter, length, and insulation for wood burners, multi-fuel stoves and gas fires per UK Building Regs Approved Document J.

From stove connection to chimney top

Nominal heat output — check stove spec sheet

Determines minimum liner diameter

Internal width of chimney void. Standard: 225mm

Bends in Flue Route

Each adds ~0.5m to liner length

Each adds ~1.0m to liner length. Avoid if possible.

Rain cap is standard; anti-downdraught for exposed locations

Include vermiculite insulation

Recommended — improves draught and reduces condensation

Enter price per metre for a liner cost estimate

How We Calculate This

This calculator determines the correct flue liner diameter based on your stove output and fuel type, then calculates the total liner length needed (including allowance for bends), and estimates vermiculite insulation bags.

Flue liner sizing (Approved Document J)

  • Wood/multi-fuel up to 20kW: minimum 150mm (6") diameter
  • Gas fire/stove: minimum 125mm (5") diameter
  • Over 20kW: minimum 200mm (8") diameter

Liner length calculation

Total liner length = Chimney height + Bend allowances

  • Each 45-degree bend adds approximately 0.5m
  • Each 90-degree bend adds approximately 1.0m
  • Maximum 4 bends allowed per Approved Document J

Vermiculite insulation

Vermiculite is poured into the void between the flue liner and the chimney wall. The volume is calculated from the chimney internal diameter, liner external diameter, and chimney height. One 100-litre bag covers approximately 2m of liner in a standard 225mm internal chimney.

Chimney height requirements

Minimum 4.5m total flue height for adequate draught. The flue must terminate at least 600mm above the ridge if within 2.3m, or 1m above any roof surface within 2.3m (Approved Document J, Diagram 25).

Standards

UK Building Regulations Approved Document J (Combustion appliances and fuel storage systems). Flue liners per BS EN 1856-2 (metal liners). Flue system design per BS EN 15287.

Frequently Asked Questions

Last updated: February 2026

All calculations are estimates. Verify with your supplier.